ByePass Gadget:

  • Collect two nos. of BP-FP BY-PASS Coupling from pantry car/AC II or Guard Cab as per Provision Made.
  • Close the Fp and BP out off angle cocks of loco end adjacent coach and the affected coach respectively.Wait till pressure of both air hoses releases
  • Uncouple BP and FP air hoses, Couple BP-FP BYPASS Coupling between BP air hose of loco end adjacent coach and FP air hose of the affected coach.
  • Similarly close cut off angle cocks of FP and BP of rear end adjacent coach and the affected coach.Uncouple Bp and FP air hoses.COuple BP-FP BYPASS coupling between BP air hose of rear end adjacent coach and FP air hose of the affected coach.
  • Open cut off angle cocks of BP of rear end adjacent coach, both FP cut off angle cocks of affected coach and BP cut off angle cock loco end adjacent coach respectively
  • Manually Release and Isolate the affected coach
  • Conduct air pressure continuity test and work the train